Product Overview:The EXKPT1-12-30 belt protection switch is a high-performance deviation switch designed specifically for belt conveyor systems. This switch can effectively monitor the deviation of the belt and trigger an alarm or control signal in case of abnormalities to protect the conveying equipment from damage. EXKPT1-12-30 has reliable performance and durable design, suitable for various industrial environments.
Main features:
Accurate detectionEXKPT1-12-30 adopts a high-sensitivity sensor, which can accurately detect the deviation of the belt and issue an alarm when the deviation reaches the set value.
Dual level alarm functionThe switch is equipped with a dual level alarm function, which can emit different alarm signals according to the degree of belt deviation. Primary alarm is used for slight deviation to remind operators to adjust; Advanced alarm triggers a shutdown signal when the offset is severe to prevent equipment damage.
Durable designMade of high-strength materials, it has excellent wear resistance and corrosion resistance, suitable for use in harsh environments.
Protection levelWith an IP65 protection level, it can effectively prevent the intrusion of dust and moisture, and is suitable for various industrial environments, including high dust and humid environments.
Multiple output modesSupports normally open and normally closed contact outputs, making it easy to integrate with different types of control systems.
Easy to install and maintainCompact design, easy installation, convenient daily maintenance, reducing maintenance costs and time.
Technical parameters:
working principle:The EXKPT1-12-30 belt protection switch monitors the movement status of the belt through a built-in sensor. When the belt deviation exceeds the set angle range, the device will trigger an alarm or control signal. The dual level alarm function can issue different alarms in different degrees of deviation, timely reminding operators to take necessary measures to ensure the safety and stability of the belt conveyor system.
Application scenarios:
Installation and maintenance:
Installation locationEXKPT1-12-30 should be installed at critical locations on the belt conveyor, such as on both sides or in the middle section, to ensure effective detection of belt deviation.
Wiring debuggingConnect the wires correctly according to the product manual, ensuring that the power and signal lines are connected correctly. After installation, debug and check if the device's functions are normal, including whether the triggering of alarms and control signals meets the set requirements.
Regular inspectionRegularly check the operation status of the equipment, especially when used in high dust or high humidity environments, pay attention to the maintenance and upkeep of the equipment.
Cleaning and maintenanceRegularly clean the surface of the equipment to prevent the accumulation of dust and dirt. It is recommended to conduct a comprehensive functional test every six months to ensure the normal operation of the equipment.
Safety precautions:
Summary:The EXKPT1-12-30 belt protection switch is an efficient and reliable monitoring device with dual level alarm function and high-precision detection capability. Its IP65 protection level and durable design enable it to operate stably in harsh environments, making it an important equipment for ensuring the safety of belt conveyor systems.
1. How does the dual level alarm function of EXKPT1-12-30 belt protection switch help improve the safety of the belt conveyor system?
The dual level alarm function of EXKPT1-12-30 enables the equipment to issue a primary alarm when there is a slight deviation in the belt, reminding the operator to make adjustments and avoiding further deterioration of the problem. When the offset is severe, the equipment will trigger advanced alarms or automatic shutdown signals to prevent equipment damage or production interruption. This hierarchical alarm mechanism improves the response speed and processing capability of the system, helping to ensure the safety and reliability of the belt conveyor system.
2. How to choose the appropriate installation location to maximize the effectiveness of the EXKPT1-12-30 belt protection switch?
EXKPT1-12-30 should be installed at critical locations on the belt conveyor, such as on both sides or in the middle section, to effectively monitor the deviation of the belt. During installation, ensure that the sensor of the switch can accurately sense the movement status of the belt, and avoid installing in areas with high vibration or covered by materials. The correct installation position can improve monitoring effectiveness, timely detect and correct belt offset problems.
3. What is the service life of the EXKPT1-12-30 belt protection switch in high dust environments?
EXKPT1-12-30 has an IP65 protection level, which can effectively prevent the intrusion of dust and moisture, thus ensuring stable operation in high dust environments. However, high dust environments may still have an impact on the service life of equipment. To extend the lifespan of the equipment, it is recommended to regularly clean and maintain it to avoid dust accumulation and damage to the equipment. Regularly inspect the operational status and functional testing of equipment to ensure its reliability and long-term stability.