Current location:sensor >

Deviation Switch JJK1-A-R485-W Product Description

  • 2024-08-26 14:28:51
  • 0
 

跑偏开关JJK1-A-R485-W 产品说明

Product Overview
The deviation switch JJK1-A-R485-W is an efficient safety protection device used in conveyor belt systems. It can detect the deviation of the conveyor belt in a timely manner and issue a stop signal to prevent equipment damage and safety accidents. This equipment is widely used in industries such as mining, ports, power plants, and chemical plants to ensure the safe operation of belt conveyors.

Product Features

  1. Accurate detectionJJK1-A-R485-W adopts high-precision sensors that can monitor the deviation of the conveyor belt in real time, with high detection sensitivity to ensure timely response.

  2. durableThe equipment casing is made of high-strength cast aluminum or stainless steel material, which has excellent corrosion resistance and impact resistance, and is suitable for harsh industrial environments.

  3. Bidirectional triggeringSupport bidirectional monitoring, the equipment can accurately detect and send signals regardless of whether the conveyor belt deviates to the left or right.

  4. Remote monitoringBuilt in RS485 communication interface, supporting remote monitoring and data transmission. Users can monitor switch status in real time through the industrial bus for centralized management.

  5. High protection levelCompliant with IP65 protection standard, with waterproof and dustproof functions, suitable for harsh working environments such as humidity and dust.

working principle
When the conveyor belt deviates, the sensor of JJK1-A-R485-W will detect the deviation angle and trigger the internal switch, immediately issuing an alarm signal or stopping command to prevent further deviation or damage of the conveyor belt. Meanwhile, through the RS485 interface, the device status can be transmitted to the control center for remote monitoring and management.

technical parameter

  • modelJJK1-A-R485-W
  • Detection angleAdjustable from ± 10 ° to ± 30 °
  • contact rating:AC 380V/10A
  • Protection level:IP65
  • working temperature-30 ℃ to+70 ℃
  • communication interface:RS485
  • Output format: Normally open/normally closed contact output
  • Shell material: Cast aluminum/stainless steel (optional)

Application scenarios
JJK1-A-R485-W deviation switch is suitable for various belt conveyor systems that require strict monitoring of the operating status of the conveyor belt, especially in industrial places such as mines, ports, power plants, and chemical plants. Its precise detection capability and remote monitoring function can effectively prevent safety accidents caused by conveyor belt deviation, ensuring the continuity and safety of production.

Installation and maintenance

  • installInstall the deviation switch on the brackets on both sides of the conveyor belt, ensuring that the sensing device of the equipment is at an appropriate distance from the edge of the conveyor belt. The installation position should be in an area where the conveyor belt is prone to deviation.
  • maintainRegularly check the detection sensitivity of the equipment and the status of the communication interface to ensure that the equipment can work properly. Clean the surface of the sensor to avoid dust and foreign objects affecting the detection effect.

epilogue
The deviation switch JJK1-A-R485-W is a conveyor belt protection device that integrates high-precision detection, durability, and intelligence. It plays an important role in ensuring equipment safety, reducing downtime, and lowering maintenance costs, and is suitable for conveyor systems in modern industry that require high safety and efficiency.



Related Q&A FAQs:

1. How to adjust the detection angle of the deviation switch JJK1-A-R485-W?

The detection angle of the deviation switch JJK1-A-R485-W can be adjusted between ± 10 ° and ± 30 °. The adjustment method is set through the adjustment bolt on the equipment. Users can choose the appropriate detection angle based on the specific operation and deviation risk of the conveyor belt, ensuring that the equipment can detect deviation in a timely manner and issue an alarm signal.

2. What is the function of the RS485 communication interface of the deviation switch JJK1-A-R485-W?

The RS485 communication interface of JJK1-A-R485-W is used to transmit the operating status and alarm information of the equipment to the remote control system. Through this interface, users can monitor the operation of the conveyor belt in real-time in the control room, achieve remote alarm and control, and improve the efficiency and safety of production management.

3. What are the options for the housing material of the deviation switch JJK1-A-R485-W?

The housing material of the deviation switch JJK1-A-R485-W has two options: cast aluminum and stainless steel. The cast aluminum shell is lightweight and has good corrosion resistance, suitable for general industrial environments; The stainless steel shell is more sturdy and suitable for working environments with strong corrosiveness or extreme temperatures. Users can choose suitable materials based on their specific usage environment.

Guess you like it